HP (Hewlett-Packard) C30 Printer User Manual


 
Printer and Troubleshooting Overview 1-9
Jogger Errors
081 PCL board activated the jogging motor but did not detect a change
in the signal from the front sensor in the job offset assembly (diag-
nostic test only).
082 PCL board activated the jogging motor but did not detect a change
in the signal from the rear sensor in the job offset assembly (diag-
nostic test only).
083 PCL board activated the jogging motor but did not detect a change
in the signal from either the front or rear sensors in the job offset
assembly.
084 PCL board detected a signal from the duplex control board #2 indi-
cating that the registration side sensor did not activate after com-
mand was sent to the duplex control board #2 to turn on the resist
motor (diagnostic test only).
085 PCL board detected a signal from the duplex control board #2 indi-
cating that the registration side sensor did not deactivate after a
command was sent to the duplex control board #2 to turn on the
resist motor (diagnostic test only).
086 PCL board detected a signal from the duplex control board #2 indi-
cating that either the registration side sensor was activated and
would not deactivate or was deactivated and would not activate
after a command was sent to the duplex control board #2 to turn on
the resist motor.
LVPS Errors
090 PCL board detected that one of the cover interlocks was not acti-
vated (diagnostic test only).
097 PCL board detected a signal from the IGS board indicating the
absence of +12 Vdc.
098 PCL board detected a signal from the IGS board indicating the
absence of ‚-12 Vdc.
099 PCL board detected a signal from the IGS board indicating the
absence of +24 Vdc.
Controller Errors
100, 102 IGS board detected a failure of the PCL board status codes.
101 PCL board detected that the IGS board was in a halt state (diag-
nostic test only).
121-127 PCL board detected an error in the communication between the
PCL board and the IGS board.
130-134 PCL board detected an error during the internal diagnostic testing
of the PCL board.
140 PCL board detected an error during the internal diagnostic testing
of the PCL board.
145 PCL board detected an error during the internal diagnostic testing
of the PCL board.
160-182 PCL board detected an error during the internal diagnostic testing
of the PCL board.
199-215 PCL board detected an error in the communication between the
PCL board and the IGS board.
301-401 IGS board detected an error during the internal diagnostic testing
of the IGS board.
Table 1-1. Error Code Technical Definitions (Continued)
Type Error Description