HP (Hewlett-Packard) C3000 Personal Computer User Manual


 
Chapter 3 61
Troubleshooting
Selftest Failures
Chassis Codes
Table 3-2. lists all of the chassis codes for the B1000 and C3000 workstations.
Table 3-2. Chassis Codes for B1000/C3000 Workstations
Ostat Code FRU Message Description
FLT 1n01 SYS BD HPMC occurred CPU n detected an unexpected HPMC.
FLT 1n02 SYS BD powerfail intrpt CPU n detected an unexpected power fail
interrupt.
FLT 1n03 SYS BD recvry cntr trap CPU n detected an unexpected recovery
counter trap.
FLT 1n04 SYS BD external intrrpt CPU n detected an unexpected external
interrupt.
FLT 1n05 SYS BD LPMC occurred CPU n detected an unexpected LPMC.
FLT 1n06 SYS BD ITLB mis/Ipg flt CPU n detected an unexpected ITLB miss
or instruction page fault.
FLT 1n07 SYS BD I mem prot trap CPU n detected an unexpected instruction
memory protection trap.
FLT 1n08 SYS BD illegal inst trp CPU n detected an unexpected illegal
instruction trap.
FLT 1n09 SYS BD break instr trap CPU n detected an unexpected break
instruction trap.
FLT 1n0A SYS BD privilgd op trap CPU n detected an unexpected privileged
operation trap.
FLT 1n0B SYS BD privlgd reg trap CPU n detected an unexpected privileged
register trap.
FLT 1n0C SYS BD overflow trap CPU n detected an unexpected overflow
trap.
FLT 1n0D SYS BD conditional trap CPU n detected an unexpected conditional
trap.
FLT 1n0E SYS BD assist exep trap CPU n detected an unexpected assist
exception trap.
FLT 1n0F SYS BD DTLB mis/Dpg flt CPU n detected an unexpected DTLB
miss or data page fault.
FLT 1n10 SYS BD non-acc ITLB mis CPU n detected an unexpected non-access
ITLB miss fault.
FLT 1n11 SYS BD non-acc DTLB mis CPU n detected an unexpected non-access
DTLB miss or data page fault.
FLT 1n12 SYS BD data mem prot tr CPU n detected an unexpected data
memory protection trap.