HP (Hewlett-Packard) C3000 Personal Computer User Manual


 
Chapter 3 81
Troubleshooting
Selftest Failures
OFF CBD0 IO BD R2PCI T-Abort;OV Rope-to-PCI bridge signalled multiple
Target Aborts.
OFF CBD2 IO BD PCI parity err PCI address/command parity error.
OFF CBD4 IO BD PCI par err; OV Multiple PCI address/command parity
errors.
OFF CBD6 IO BD PCI no DEVSEL# No PCI device selected (DEVSEL#
assertion). I/O error log word 3 contains
the error address.
OFF CBD8 IO BD PCI no DEVSEL;OV Multiple DEVSEL# assertions. I/O error
log word 3 contains the error address.
OFF CBDA IO BD PCI target abort A PCI device signalled Target Abort. I/O
error log word 3 contains the error
address.
OFF CBDC IO BD PCI T-Abort; OV A PCI device signalled multiple Target
Aborts. I/O error log word 3 contains the
error address.
OFF CBDD IO BD PCI assrts LOCK# A PCI device asserted LOCK#.
OFF CBDE IO BD PCI LOCK#; OV A PCI device asserted LOCK# multiple
times.
OFF CBE0 IO BD PCI assrts SERR# A PCI device asserted SERR#: address
parity error or other system error.
OFF CBE2 IO BD PCI SERR#; OV A PCI device asserted SERR# multiple
times.
OFF CBE3 IO BD Unknown PCI err Unknown PCI error detected.
OFF CBE6 SYS BD AtoE rope perr Parity error between system I/O controller
and Rope-to-PCI bridge.
OFF CBE7 IO BD R2PCI intrnl err Rope-to-PCI bridge internal data error.
OFF CBE8 SYS BD AtoE rope perr Command parity error between system
I/O controller and Rope-to-PCI bridge.
OFF CBE9 IO BD Unknown Rope err Unknown rope error occurred.
FLT CBF0 SYS BD HPMC initiated A High-Priority Machine Check entered
the firmware HPMC handler.
FLT CBF1 SYS BD no OS HPMC IVA There is no HPMC vector for the
operating system. Firmware will halt the
CPU, requiring a power cycle to recover.
Table 3-2. Chassis Codes for B1000/C3000 Workstations
Ostat Code FRU Message Description