8. Align the fuser unit over an appropriate waste container, such
as an old jar, and tilt the unit so the excess oil pours into the
container (fig. 6.7). Then, dispose of the oil following safety
laws and regulations.
9. Use a clean, dry, lint-free cloth or some cotton swabs to wipe
any remaining oil out of the tray.
10. Replace the fuser unit.
11. Stuff a clean, wadded paper towel into the place normally
occupied by the oil bottle to act as a cushion and to absorb any
residual oil during the move.
12. After the move, see “Replacing the Cleaning Pad and Oil
Bottle,” earlier in this chapter, for instructions on reinstalling
the oil bottle.
Fig. 6.7 Drain Oil from Fuser Unit