IBM 1xR Printer User Manual


 
Error Conditions:
If an image cannot be printed, status byte 7, bit 2 will be set. This may
happen when the image is too big to print. Try decreasing the ECC level.
Select PDF417 ECC (error correction codewords) level
Syntax:
GS R n or X'1D;52;n1;n2'
Where:
n1 The high-order byte of the ECC level.
n2 The low-order byte of the ECC level.
Default:
n1=00
n2=15
Range:
0 n1n2 400 decimal (170 hex)
Remarks:
For 0 n1n2 8, the ECC level is assumed as that particular security level.
The security level determines the number of error correction code words
added to the symbol.
Error Correction
Security Level Codewords
0 0
1 2
2 6
3 14
4 30
5 62
6 126
7 254
8 510
For 9 n1n2 400, the ECC level is assumed as a percentage of the
codewords in the bar code.
Select aspect ratio PDF417 bar code
Syntax:
GS S r;c or X'1D;53;r;c'
Where:
r The height dimension for the ratio; 1 r 9.
c The width dimension for the ratio; 1 c 9.
Default:
r=1,c=2
Chapter 2. Communication parameters 63