IBM Dock I Laptop User Manual


 
6.
The SCSI FIXED/REMOVAL
DRIVE MENU appears. This
menu lists 7 possible test
options. If your installation has
no hard disk drives, only Test
Options 0, 1, 2, 3, and 4 appear
on this menu. The individual
tests are described briefly below
the figure of the menu.
Adapter Diagnostics Three pass/fail tests are run on the SCSI
controller to check ROM, RAM, and the SCSI data bus.
Device Diagnostics This function issues the Device Diagnostics
command to the selected device. If the device is a removable media
type, it prompts for media to be inserted. If the command
completes successfully, the selected device is installed and
functioning properly.
Test Unit Ready This command is issued to each device to check
that the device is online and ready to accept command requests.
Get Device Status If either the Test Unit Ready, Read, or
Read/Write test resulted in an error condition, you should run Get
Device Status to isolate the specific problem causing the error
condition.
Read Test This test issues Read commands from the beginning to
the end of the entire drive to verify that the drive processes them
properly.
Chapter 5. Using the SCSI Controller and Support Software 5-23