Using EDF with your task-related user exit program
If your exit program sets the EDF bit in the schedule flag word and EDF is active,
the exit program is invoked before and after each API request to format screens for
EDF to display.
Communication between the task-related user exit and EDF is controlled by the
task-related user exit interface. The command flow between this interface, EDF, and
the task-related user exit is summarized in Figure 11 on page 302.
DFHEISTG DSECT
*
* Local working storage for CSECT JTRUE1B
*
RSA DS 18F Register save area
SA DSECT Register save area DSECT
DS F
*
RSACB DS F +004
RSACF DS F +008
RSAR14 DS F +00C
RSAR15 DS F +010
RSAR0 DS F +014
RSAR1 DS F +018
RSAR2 DS F
RSAR3 DS F
RSAR4 DS F
RSAR5 DS F
RSAR6 DS F
RSAR7 DS F
RSAR8 DS F
RSAR9 DS F
RSAR10 DS F
RSAR11 DS F
RSAR12 DS F
DFHREGS
DFHUEXIT TYPE=RM
DFHEISTG
DFHEIEND
PRINT NOGEN
PRINT GEN
END
Figure 10. Sample code for a task-related user exit program to be invoked at CICS termination (part 2)