Table 50. LOGON mode table and ISTINCLM entries (continued)
RN VTAM MODEENT macro entries that are needed for related
CICS TYPETERM definitions
Suitable
supplied
entries
19
FMPROF=X’03’
TSPROF=X’03’
PRIPROT=X’B1’
SECPROT=B’10..0000’
COMPROT=B’0011.000 10000.00’
PSERVIC=B’00000011 10000000 00000000 00000000
00000000 00000000 aaaaaaaa bbbbbbbb
cccccccc dddddddd eeeeeeee’
BLK3790
DSC2K
DSC4K
D6328902
D6328904
See note 1
20
FMPROF=X’04’
TSPROF=X’03’
PRIPROT=X’31’
SECPROT=X’B0’
COMPROT=B’0111.000’
21
FMPROF=X’04’
TSPROF=X’04’
PRIPROT=X’50’
SECPROT=X’10’
COMPROT=B’0000.000 00000.00’
22
FMPROF=X’04’
TSPROF=X’04’
PRIPROT=X’B0’
SECPROT=X’B0’
COMPROT=B’0100.000 00000.00’
IBMS3650
23
FMPROF=X’04’
TSPROF=X’04’
PRIPROT=X’B1’
SECPROT=X’B0’
COMPROT=B’0111.000 00000.00’
24
TYPE=X’00’
FMPROF=X’13’
TSPROF=X’07’
PRIPROT=X’B0’
SECPROT=X’B0’
COMPROT=B’.101.000 10110.01’
PSERVIC=B’00000110 00000010
........ 00000000 00000000 00000000
........ 00000000 00000000 00000000
........ 0010..00’
Notes:
1. PSERVIC (RN 18 and 19): BYTE 2 BIT 0 should be set on where extended data stream
(EXTDS) support is required.
2. RN 11 or 13 is used to determine the MODEENT macro operands for device
SCSPRINT. However, if you have specified any of the attributes EXTENDEDDS,
COLOR, PROGSYMBOLS, HILIGHT, SOSI, OUTLINE, QUERY(COLD), or QUERY(ALL)
for the TYPETERM, then the COMPROT parameter of RN 13 should be modified to
read COMPROT=B'0111.000 10000.00'.
3. This LOGMODE may be used for either device type 4700 in half duplex mode or device
types BCHLU, 3770, 3770B and 3790 with SESSIONTYPE(USERPROG). To enable
these devices to be autoinstalled with the correct model, the model names list supplied
to the autoinstall exit will list the names of models defined as DEVICE(3600) after the
names of all other eligible models. The exit can be coded to select a name from the end
of the list for a 4700 half duplex device.
Appendix A. Coding entries in the VTAM LOGON mode table 839