Intel® Server Board SDS2 Errata Listing
Revision 1.2
Order Number: A85874-002
109
in BIOS Setup, the following error message will appear when attempting to
update the FRU/SDR files:
Updating the FRU and Sensor Data Records
Packaged file is corrupt
Implication: If console redirection is set to enabled in BIOS Setup, the Intel Server Board
SDS2 FRU/SDR files cannot be updated.
Workaround: Make sure that console redirection is set to disabled in BIOS Setup (this is the
default BIOS setting) before performing a FRU/SDR file update.
Status: Fixed. This issue is fixed in SDS2 BIOS Production Release 2.1 (Build 44) and
later versions.
4. First characters and arrow keys not echoed with console
redirection
Problem: Two issues occur with console redirection on the Intel® Server Board SDS2:
1. When booting to ROM DOS under console redirection, the first character of
a command is not echoed to the screen until the Enter key is pressed.
2. In BIOS Setup under console redirection, the arrow keys are not properly
echoed when pressed.
Implication: The first character and arrow keys are not correctly echoed to the screen with
console redirection.
Workaround: The user can workaround this issue by pressing the Enter key or by pressing
the arrow keys several times.
Status: Fixed. This issue is fixed in SDS2 BIOS Production Release 2.1 (Build 44) and
later versions.
5. Intel® & ICP Vortex* RAID Controllers will cause the Intel®
Server Board SDS2 to halt during POST when the BIOS Logo
screen is enabled
Problem: When booting the Intel Server Board SDS2 with an Intel RAID Controller or ICP
Vortex* RAID controller installed, the system will halt during POST when the
Intel Server Board SDS2 BIOS Logo screen is enabled. This issue occurs only
with Intel RAID Controllers running with version 6.2.6i firmware and ICP Vortex
Controllers running version 28 firmware. Intel has found the root cause of this
issue to be an INT 10 BIOS video interrupt call during RAID POST. The Intel