Intel SDS2 Server User Manual


 
BIOS Intel® Server Board SDS2
Revision 1.2
Order Number: A85874-002
64
Feature Option Description
Assert NMI on PERR Disabled
Enabled
If enabled, PCI bus parity error (PERR) is
enabled and is routed to NMI.
Assert NMI on SERR Enabled
Disabled
If enabled, PCI bus system error (SERR) is
enabled and is routed to NMI.
FRB-2 Policy FRB2 Disable
Disable Immediately
Never Disable
Allow 3 Failures
Controls the policy of the FRB-2 timeout. This
option determines when the Boot Strap
Processor (BSP) should be disabled if FRB-2
error occur. And Detemines when FRB2 stop.
Thermal Sensor Disabled
Enabled
Determines wheter Thermal Sensor monitoring
function
BMC IRQ IRQ11
IRQ5
IRQ10
Disabled
Determines BMC IRQ.
Post Error Pause Disabled
Enabled
If enabled, the boot is stopped when Post error
occurs.
AC Link Power On
Last State
Stay off
Selects system power state after AC loss.
Table 46. System Management Submenu Selections
Feature Option Description
BIOS Version Information field only
Board Part Number Information field only
Board Serial Number Information field only
Sys tem Part Number Information field only
System Serial Number Information field only
Chassis Part Number Information field only
Chassis Serial Number Information field only
BMC Device ID Information field only.
BMC Device Revision Information field only.
BMC Firmware Revision Information field only.
BMC Firmware BootBlock Revision Information field only.
BMC Support IPMI Version Information field only.
SDR Revision Information field only.
PIA Revision Information field only.
Primary HSBP Revision Information field only, hidden if not detected
Secondary HSBP Revision Information field only, hidden if not detected