Intel SDS2 Server User Manual


 
Intel® Server Board SDS2 Table of Contents
Revision 1.2
Order Number: A85874-002
vii
8.9 Connector Manufacturers and Part Numbers..................................................................87
9. Jumpers..................................................................................................................................88
9.1 System Configuration Jumpers........................................................................................88
9.2 Performing CMOS Clear, BIOS Recovery, and BMC Force Update...............................92
9.2.1 Performing CMOS Clear.............................................................................................92
9.2.2 Performing BIOS Recovery Boot................................................................................92
9.2.3 Performing BMC Force Update ..................................................................................93
10. Electrical and Thermal Specifications ...............................................................................94
10.1 Absolute Maximum Ratings...........................................................................................94
10.2 Power Consumption......................................................................................................94
10.3 Power Supply Specification...........................................................................................95
10.3.1 Power Timing ............................................................................................................95
10.3.2 Voltage Recovery Timing Specifications...................................................................98
10.4 Estimateded Server Board MTBF...............................................................................100
11. Mechanical Specifications.................................................................................................101
12. Regulatory and Integration Information...........................................................................102
12.1 Regulatory Compliance...............................................................................................102
12.2 Installation Instructions ................................................................................................103
12.2.1 Ensure EMC ............................................................................................................103
12.2.2 Ensure Host Computer and Accessory Module Certifications ...............................104
12.2.3 Prevent Power Supply Overload.............................................................................104
12.2.4 Place Battery Marking on Computer .......................................................................104
12.2.5 Use Only for Intended Applications .........................................................................105
12.2.6 Installation Precautions ...........................................................................................105
12.2.7 External ICMB Cable Information ............................................................................105
13. Errata Listing.......................................................................................................................106
13.1 Summary Errata Table................................................................................................106
13.2 Errata...........................................................................................................................108
1. Intel® RAID controller SRCMR not yet supported with Intel® Server Board SDS2.......108
2. Intel® Server Board SDS2 BIOS update utility does not allow updates from a PXE
Server or from network drives ..................................................................................................108
3. Intel® Server Board SDS2 FRU/SDR update fails with console redirection enabled in
BIOS Setup...............................................................................................................................108
4. First characters and arrow keys not echoed with console redirection ..........................109