Intel SDS2 Server User Manual


 
BIOS Intel® Server Board SDS2
Revision 1.2
Order Number: A85874-002
40
Sensor
Name
Sensor
#
Sensor Type
Event/
Reading
Type
Event
Offset
Triggers
Power Unit
Status
01h
Power Unit -
09h
Sensor
Specific - 6Fh
Power Off,
Power Cycle,
A/C Lost,
Power Unit
Redundancy
02h
Power Unit -
09h
Generic 0Bh
Redundancy Regain
Redundancy lost
Watchdog 03h
Watchdog2
23h
Sensor
Specific - 6Fh
Timer Expired,
Hard Reset,
Power Down,
Power Cycle,
Timer Interrupt
Platform
Security
Violation
04h
Platform
Security
Violation
Attempt - 06h
Sensor
Specific - 6Fh
- Secure mode
violation attempt,
- Out-of-band access
password violation
Physical
Security
Violation
05h
Physical
Security - 05h
Sensor
Specific - 6Fh
General Chassis
Intrusion,
LAN Leash Lost
POST Error 06h
System
Firmware
Progress 0Fh
Sensor
Specific - 6Fh
POST error
FP Diag
Interrupt (NMI
for IA-32, INIT
for IA-64)
07h
Critical
Interrupt - 13h
Sensor
Specific - 6Fh
Front Panel NMI
Memory 08h Memory 0Ch
Sensor
Specific - 6Fh
Correctable ECC,
Uncorrectable ECC
Event
Logging
Disabled
09h
Event Logging
Disabled 10h
Sensor
Specific - 6Fh
Correctable Memory
Error Logging
Disabled,
Log Area
Reset/Cleared
BB +1.25V 0Ah Voltage 02h
Threshold -
01h
-
BB +2.5V 0Bh Voltage 02h
Threshold -
01h
-
BB +3.3V 0Ch
Voltage 02h
Threshold -
01h
-
BB +3.3V
Standby
0Dh
Voltage 02h
Threshold -
01h
-
BB +5V 0Eh Voltage 02h
Threshold -
01h
-
BB +12V 0Fh Voltage 02h
Threshold -
01h
-