Juniper Networks J2320 Network Router User Manual


 
user@host# set chassis fpc 2 offline
If the power and heat tokens no longer exceed the maximum, the PIMs that
were placed offline by J-series power management are brought online
automatically.
Use the set chassis disable_power_management command to disable J-series
power management:
user@host# set chassis disable_power_management
CAUTION: Use extreme caution when disabling J-series power management. To
prevent equipment damage, do not install a combination of PIMs that exceeds the
power or heat capacity of your router when J-series power management is disabled.
The set chassis disable_power_management command brings the offline
PIMs online automatically.
To reenable J-series power management, remove the configuration statement. For
detailed information about the set chassis fpc offline and set chassis
disable_power_management configuration statements, see the JUNOS System Basics
Configuration Guide.
Contacting the Juniper Networks Technical Assistance Center
If you need assistance while troubleshooting a Services Router, open a support case
using the Case Manager link at http://www.juniper.net/support/, or call 1-888-314-JTAC
(within the United States) or 1-408-745-9500 (from outside the United States). For
more information, see Contacting Customer Support and Returning
Hardware on page 215.
214 Contacting the Juniper Networks Technical Assistance Center
J2320, J2350, J4350, and J6350 Services Router Getting Started Guide