Juniper Networks M5 Network Router User Manual


 
Maintain the Rout
ing Engine
Verify that the air flow in and out of cooling system components is not obstructed.
Maintain the Routing Engine
The Routing En
gine installs into a slot in the Forwarding Engine Board (FEB) at the
rear of the chassis, as shown in Figure 3. To maintain the Routing Engines, issue the
CLI show chassis routing-engine command on a regular basis to check the status of the
Routing Engin
e:
user@host> show chassis routing-engine
Routing Engin
e status:
Temperature 35 degreesC/95degrees F
DRAM 768 MB
Memory utiliz
ation 16 percent
CPU utilization:
User 0 percent
Background 0 pe
rcent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percen
t
Model RE-2.0
Serial ID f1000004f91d2901
Start time 2003-
05-01 15:07:12 PDT
Uptime 3 days, 9 hours, 4 minutes, 5 seconds
Load averages: 1 minute 5 minute 15 minute
0.04 0.01 0.00
For further description of the output from the command, see the JUNOS Internet Software
Operational Mode Command Reference: Protocols, Class of Service, Chassis, and Management.
Maintain Hardware Components
79