McDATA IPS4300 Switch User Manual


 
A-2
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Event Code Tables
0 - informational.
2 - minor.
3 - major.
4 - severe (not operational).
Explanation - an explanation of what caused the event.
Action - the recommended course of action (if any) to resolve the
problem.
Event data - supplementary event data (if any) that appears in the
event log in hexadecimal format.
Distribution - checks in associated fields indicate where the event
code is reported (product, management server, or attached host).
System Events (000 through 199)
Event Code: 011
Message: Login Server database invalid.
Severity: Minor.
Explanation: Following an initial machine load (IML) or firmware download, the Login Server database failed cyclic redundancy
check (CRC) validation. All fabric service databases initialize to an empty state, resulting in implicit fabric logout
of all attached devices.
Action: Perform a data collection and return the CD to support personnel.
Event Data: No supplementary data included.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔