Maintenance Analysis Procedures
3-19
Maintenence Analysis Procedures
4
A connection is not allowed because of a conflict with the configured
port type. An expansion port (E_Port) is cabled to a Fibre Channel
device or a fabric port (F_Port) is cabled to a director or fabric switch.
a. Select Ports and Basic Info from the Configure menu at any
view. The Basic Information View displays.
b. If necessary, use the vertical scroll bar to display the information
row for the port indicating an invalid attachment.
c. Select (click) the Type field and configure the port as follows:
• Select fabric port (F_Port) if the port is cabled to a device.
• Select expansion port (E_Port) if the port is cabled to a
director or switch (ISL).
d. Click OK or Activate.
05 Loopback plug connected. Go to step 6.
06 N-Port connection not allowed. Go to step 4.
07 Non-McDATA switch at other end. Go to step 5.
08 E_Port capability disabled. Go to step 7.
0A Unauthorized port binding WWN. Go to step 2.
0B Unresponsive node. Go to step 8.
0C ESA security mismatch. Go to step 10.
0D Fabric binding mismatch. Go to step 11.
0E Authorization failure reject. Go to step 8.
0F Unauthorized switch binding WWN. Go to step 10.
10 Authentication failure Go to step 12.
11 Fabric mode mismatch. Go to step 5.
Table 3-9 Invalid Attachment Reasons and Actions (Continued)
Byte 4 Invalid Attachment Reason Action