McDATA IPS4300 Switch User Manual


 
Event Code Tables
A-25
Event Code Tables
CTP Card Events (400 through 499)
Event Code: 400
Message: Power-up diagnostics failure.
Severity: Major.
Explanation: Power-on self tests (POSTs) detected a failed FRU as indicated by the event data.
Action: If a CTP card, fan, or power supply failure is indicated, replace the switch. Perform a data collection and return
the CD to support personnel.
Event Data: Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply assembly.
Byte 1 = FRU slot number.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔
Event Code: 410
Message: Switch reset.
Severity: Informational.
Explanation: The switch reset due to system power-up, IML, or manual reset. A software reset can occur automatically after a
firmware fault (event code 411), or be user-initiated. Event data indicates the type of reset.
Action: No action required.
Event Data: Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log