Maintenance Analysis Procedures
3-5
Maintenence Analysis Procedures
MAP 0000: Start MAP
This MAP describes initial fault isolation beginning at the:
•Failed product.
• Browser-capable PC with Internet connectivity to the firmware-
resident Enterprise Fabric Connectivity Manager (EFCM) Basic
Edition interface.
• Product-attached open systems interconnection (OSI) host
console.
1
Prior to fault isolation, acquire:
• A system configuration drawing or planning worksheet that
includes the location of the product, management interface,
other McDATA products, and device connections.
• The internet protocol (IP) address, gateway address, and subnet
mask for the product reporting the problem.
• User IDs and passwords.
Continue to the next step.
583 Loss of signal or loss of synchronization. Go to MAP 0500.
584 Not operational primitive sequence received. Go to MAP 0500.
585 Primitive sequence timeout. Go to MAP 0500.
586 Invalid primitive sequence received for current link state. Go to MAP 0500.
810 High temperature warning (CTP thermal sensor). Go to MAP 0400.
811 Critically hot temperature warning (CTP thermal sensor). Go to MAP 0400.
812 CTP card shutdown due to thermal violations. Go to MAP 0400.
850 Switch shutdown due to CTP thermal violations. Go to MAP 0400.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code