A-38
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Event Code Tables
Event Code: 583
Message: Loss of signal or loss of synchronization.
Severity: Major.
Explanation: An attached server recognized a loss-of-signal condition or a loss-of-synchronization condition that persisted for
more than the specified receiver-transmitter timeout value (R_T_TOV).
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to MAP 0000:
Start MAP to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔
Event Code: 584
Message: Not operational primitive sequence received.
Severity: Major.
Explanation: An attached server received a not-operational primitive sequence (NOS).
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to MAP 0000:
Start MAP to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔