Mitsubishi Electronics FR-S500 Power Supply User Manual


 
90
Display function parameters
2.6 Display function parameters
2.6.1 Monitor display (Pr. 52 , Pr. 54 )
<Setting>
When "100" is set in Pr. 52, the monitored values during stop and during operation
differ as indicated below.
You can choose the display of the operation panel "monitor/frequency setting
screen".
Parameter Name
Factory
Setting
Setting
Range
Remarks
52
Operation panel
display data
selection
00, 1, 100
Setting is enabled when Pr. 30 = "1"
54
AM terminal function
selection
00, 1
POINT
You can also use the to change the display. (Refer to the instruction manual
(basic) for the operation procedure.)
The analog voltage output terminal AM is available for signal output. (Make
selection using the Pr. 54 "AM terminal function selection" value.)
Signal Type Unit
Parameter Setting
Full-Scale Value of AM
Level Meter
Pr. 52 Pr. 54
Operation panel
LED
AM terminal
Output frequency Hz 0/100 0
Pr. 55 "frequency monitoring
reference"
Output current A 1 1
Pr. 56 "current monitoring
reference"
Pr. 52
0 100
During running/stop During stop During running
Output frequency Output frequency Set frequency Output frequency
REMARKS
During an error, its definition appears.
During reset, the values displayed are the same as during a stop.
For selection of the parameter unit (FR-PU04) monitor display, refer to the communication
parameter n16 "PU main display screen data selection". (Page 152)
CAUTION
The unit displayed on the operation panel is only A and other units are not
displayed.
Related parameters
Speed display Pr. 37 "speed display" (refer to page 81)
Adjustment of AM level meter full-scale value Calibration parameter C1 "AM terminal
calibration" (refer to page 126)
Monitoring reference Pr. 55 "frequency monitoring reference", Pr. 56 "current monitoring
reference" (refer to page 92)
SET