58
Function (Parameter) list
Parameter List
Calibration parameters
* Factory settings may differ because of calibration parameters.
Func-
tion
Parame-
ters
Indi-
cation
Name Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
Calibration parameters
C1 (901)
AM terminal
calibration
126
C2 (902)
Frequency
setting voltage
bias frequency
0 to 60Hz 0.1Hz 0Hz 82
C3 (902)
Frequency setting
voltage bias
0 to 300% 0.1% 0% (*) 82
C4 (903)
Frequency setting
voltage gain
0 to 300% 0.1%
96%
(*)
82
C5 (904)
Frequency
setting current
bias frequency
0 to 60Hz 0.1Hz 0Hz 82
C6 (904)
Frequency setting
current bias
0 to 300% 0.1% 20% (*) 82
C7 (905)
Frequency setting
current gain
0 to 300% 0.1%
100%
(*)
82
C8 (269) Parameter for manufacturer setting. Do not set.
Clear parameters
CLr Parameter clear
0: Not executed
1: Parameter clear
10: All clear
10129
ECL
Alarm history
clear
0:Not cleared,
1:Alarm history
clear
10129