iR1200 Modem
74 nextel.com
Action AT&f <setting>
Query AT&v
Range
Local Flow Control (Traditional)
This parameter selects the type of flow control used between the computer and
the modem while in data transfer mode. This command is supported for
backward compatibility purposes. This command sets the method of flow
control for both directions of the computer-to-modem interface, while the +IFC
command allows for a separate setting for each direction.
!
The setting for this command may implicitly alter the
settings of the +IFC command.
Command &K
Action AT&k <setting>
Query
Range
Parameter
Values:
0 = No Flow Control (not recommended)
3 = RTS/CTS Flow Control.
4 = XON/XOFF Flow Control.
Display Current Parameter Value
This command allows the computer to view the parameter and S-register
settings for the active configuration profile.
Command &V
Action AT&fv <setting>