Query AT+wv312?
Range AT+wv312=?
Parameter
Values:
68-1500 = MTU Value Range
1006 = Default Value
Select Mobile IP Client
This parameter activates/deactivates the Mobile Node client in the DCE. The
mobile host can operate in two modes to access the iDEN
packet data
network.
Command +WV300
Action AT+wv300<MIP Mode>
Query AT+wv300?
Range AT+wv300=?
Parameter
Values:
0 = Activate Mobile Node in DCE.
1 = Deactivate Mobile Node in DCE.
Mobile IP Authentication Key
The iDEN
network uses the MIP Authentication Key to verify the authenticity
of the DCE with the Home Agent. The DCE and the Home Agent must have
identical values for this shared secret key for the DCE to satisfy the
authentication process.
NOTE: This command is applicable only when the Mobile IP Client in
the DCE is activated.
Command +WV301
Action AT+wv301<”key”>
Query
Range AT+wv301=?