Parameter
Values:
The authentication Key parameter is a text string of up
to 32 characters. Unlike most text-string parameters, the
Authentication key is a text representation of a
hexadecimal number. Therefore, only the characters 0-9
and A-F are acceptable. (The lower case character, a-f is
also acceptable).
NOTE: Although the parameter represents a numeric value,
the parameter is actually a text string, so the
parameter must be enclosed in quotation marks.
Mobile IP Session Timer
The command determines the maximum amount of time that a remote node can
be registered with its Home Agent before having to renew its registration. This
parameter sets a user preference for a value that is negotiated within the
network. During the negotiation process, the user preference may be overruled
by the network without notification.
Command +WV302
Action AT+wv302<timer>
Query AT+wv302?
Range AT+wv302=?
Parameter
Values:
1800-65534 = Second before expiration
65536 = Timer never expires
7200 = Default value
DTE IP Address
This command sets the mobile node’s permanent IP Address (also known as the