Nortel Networks 450 series Switch User Manual


 
332 Configuring SNMP
The Notification Target menu appears.
The Notification Target menu includes the following options:
/cfg/sys/adm/snmp/target <target ID>
followed by:
ip <IPaddr> Specifies the IP address to which trap
messages are sent.
IPaddr is the IP address of the SNMP
manager.
port <port>
Specifies the TCP port used by the SNMP
manager. The default is port 162.
version v1|v2c|v3
Specifies the SNMP version used by the
SNMP manager. Valid options are:
v1—SNMP version 1
v2c—SNMP version 2c
v3—SNMP version 3
The default is v2c.
del
Removes the current SNMP manager from
the Nortel SNAS configuration.
Configuring SNMP events
The Nortel SNAS supports three kinds of SNMP monitors, as defined in
the DISMAN-EVENT-MIB:
boolean —checks the value of a monitored object identifier (OID)
against a specific value, and triggers an event if the result matches a
specified operation.
threshold —compares a monitored OID against a range of values, and
triggers events if the comparison determines that the OID value is
rising too quickly, falling too quickly, or falls outside certain boundaries
existence —checks the condition of a monitored OID to determine if
it is present, absent, or changed, and triggers an event if the result
matches the specified condition
To configure monitors and events defined in the DISMAN-EVENT-MIB,
use the following command:
/cfg/sys/adm/snmp/event
The event menu appears.
Nortel Secure Network Access Switch
Using the Command Line Interface
NN47230-100 03.01 Standard
28 July 2008
Copyright © 2007, 2008 Nortel Networks
.