Nortel Networks 450 series Switch User Manual


 
334 Configuring SNMP
/cfg/sys/adm/snmp/event
followed by:
addmonitor [ <options> ]
-t <name> <OID> <value and
event>
Adds a threshold monitor and trigger as
defined in the DISMAN-EVENT-MIB.
Valid <options> are:
-c <comment>—adds a comment
-f <frequency>—the sampling
interval, in seconds. The default is 600
(10 minutes).
-o <OID>—additional objects to send
in the event
-d <OID> the delta discontinuity
OID
-D timeTicks|timeStamp|dateAnd
Time the delta discontinuity type
Other parameters are:
name a unique name you assign to
the monitor, for identification
OID the object identifier (or symbolic
name) to monitor
value and event—a combination
of an integer and an event condition,
where the integer represents the event
condition threshold that will trigger
notification. Valid combinations are:
<LowVal> FallingEvent
<HighVal> RisingEvent
<DeltaLowVal> DeltaFallingEve
nt
<DeltaHighVal> DeltaRisingEve
nt
Nortel Secure Network Access Switch
Using the Command Line Interface
NN47230-100 03.01 Standard
28 July 2008
Copyright © 2007, 2008 Nortel Networks
.