Paradyne 9128-II Network Router User Manual


 
4. Configuration Options
4-88
September 2002 9128-A2-GB20-80
Configuring SNMP Traps and Trap Dial-Out
Select SNMP Traps from the Management and Communication menu to configure
SNMP traps and dial-out when a trap is generated (see Table 4-22, SNMP Traps
and Trap Dial-Out Options).
Main Menu
Configuration
Management and Communication
SNMP
Traps
See Appendix B,
SNMP MIBs and Traps, and RMON Alarm Defaults
, for trap
format standards and special trap features, including RMON-specific traps, and
the default settings that will generate RMON-specific SNMP traps.
Access Type
Possible Settings: Read, Read/Write
Default Setting: Read
Specifies the type of access allowed for an authorized NMS when IP address validation is
performed.
Display Conditions
This option appears for each trap manager specified in the
Number of Trap Managers configuration option.
Read Allows read-only access (SNMP Get command) to the MIB objects. This includes
all objects specified as either read-only or read/write in the MIB RFCs.
Read/Write Allows read and write access (SNMP Get and Set commands) to the MIB
objects. However, access for all read-only objects is specified as read-only.
Table 4-21. SNMP NMS Security Options (2 of 2)
Table 4-22. SNMP Traps and Trap Dial-Out Options (1 of 6)
SNMP Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the FrameSaver unit sends trap messages to the currently
configured SNMP trap manager(s).
Enable Sends trap messages.
Disable Does not send trap messages.
Number of Trap Managers
Possible Settings: 1 6
Default Setting: 1
Specifies the number of SNMP management systems that will receive SNMP trap
messages from the FrameSaver unit. An NMS IP Address must be configured in the NMS
n
IP Address configuration option for each trap manager to receive trap messages.
1 6 Specifies the number of trap managers (inclusive).