Paradyne 9128-II Network Router User Manual


 
4. Configuration Options
4-42
September 2002 9128-A2-GB20-80
Action on Network Yellow Alarm
Possible Settings: None, Halt
Default Setting: Halt
Specifies the action to take on the synchronous data port when a yellow alarm is received
on the network interface. (A yellow alarm indicates a problem with the signal being
transmitted to the network.)
Display Conditions
This option only appears for Port-2 on a FrameSaver SLV 9128-II,
when Port Use is set to Synchronous Data.
None No action taken when a yellow alarm is received.
Halt Halts the transmission of data received on the synchronous data port and all ones
are sent on circuit BB (ITU 104) Receive Data (RD) and circuit CB (ITU 106)
Clear-to-Send (CTS) is deasserted to the port when a yellow alarm is received.
Network Initiated Data Channel Loopback
Possible Settings: Disable, V.54, ANSI_FT1, V.54_&_ANSI
Default Setting: Disable
Allows the initiation and termination of the Data Channel Loopback (V.54 Loop 2) to be
controlled by the receipt of a DCLB-actuate and DCLB-release sequence (either V.54, or
FT1 [ANSI] compliant sequences) from the network or far end unit. When this
configuration is enabled (V.54, FT1, or Both), receiving a DCLB-actuate sequence on a
particular port causes the unit to initiate a DCLB on that port (provided that a DCLB can
be performed based on the current state of the port and unit). Receiving a DCLB-release
sequence terminates the DCLB.
Display Conditions
This option only appears for Port-2 on a FrameSaver SLV 9128-II,
when Port Use is set to Synchronous Data.
Disable Ignores the DCLB-actuate and DCLB-release for the port.
V.54 DCLB-actuate and DCLB-release sequences that comply with the V.54 standard
for inter-DCE signaling for point-to-point circuits are recognized and will control the
initiation and termination of a DCLB (V.54 Loop 2) for the port.
ANSI_FT1 DCLB-actuate and DCLB-release sequences that comply with either the
ANSI.403, Annex B standard for in-band signaling for fractional T1 (FT1) channel
loopbacks are recognized and will control the initiation and termination of a DCLB for the
port.
V.54_&_ANSI DCLB-actuate and DCLB-release sequences that comply with either the
ANSI or V.54 standard are recognized and will control the initiation and termination of a
DCLB for the port.
Table 4-7. Data Port Physical Interface Options (5 of 5)