Paradyne 9128-II Network Router User Manual


 
11. Setting Up Network Health for FrameSaver Devices
11-4
September 2002 9128-A2-GB20-80
Configuring the Discovered Elements
Network Health sets the speed for discovered elements when it polls the unit for
the first time. For a FrameSaver SLV unit, the speed set would be the units CIR.
No additional configuration should be required. However, you should verify that all
appropriate information has been retrieved.
NOTE:
If an SLV unit does not have CIR configured, or if it is not configured correctly,
Network Health sets the units CIR to 0 Kbps. For this reason, you should
reconfigure the units CIR before Network Health polls it. If 0 Kbps is the speed
setting, you will need to edit the units CIR from Network Health.
Additional information can be edited, as well. See
Discovering Elements
in the
Network Health User Guide
for additional information.
Procedure
To change the CIR for FrameSaver SLV unit elements from Network Health:
1. Select the Edit Before Saving button at the bottom of the Discovering dialog
box once the discovery process is completed.
The Poller Configuration window opens.
2. Double-click on the first element discovered. The Modify Element dialog box
opens.
3. In the Speed box, select the Override radio button and enter the CIR for the
unit in the text box.
Letters
k
and
m
can be used as shortcuts (e.g., enter 56 k for 56 kilobits per
second, or 16 m for 16 Mbits per second).
4. Apply your changes:
Select the Apply/Next button to save your change and bring up the next
element to be edited. Continue until all newly discovered frame relay
elements have been modified before selecting the OK button.
Select the the OK button.
The Modify Element dialog box closes.
5. Select the OK button at the bottom of the Poller Configuration window. The
modified elements are saved to the database, and the units are polled.
Allow Network Health to continue polling for about a half an hour to allow time for
data to be gathered before running any reports.