Paradyne 9128-II Network Router User Manual


 
4. Configuration Options
4-98
September 2002 9128-A2-GB20-80
Port Access Level
Possible Settings: Level-1, Level-2, Level-3
Default Setting: Level-1
Specifies level of user access privilege for an asynchronous terminal connected to the
COM port. If a login is required for the port, the effective access level is determined by the
users access level. When a login is
not
required, the effective access level is determined
by this option.
NOTE: The effective access level is always the lowest one assigned to either the port
or the user. For example, if the Port Access Level assigned is Level-2, but the User
Access Level is Level-3, then only level-3 access will be permitted for the port.
Display Conditions
This option only appears when Port Use is set to Terminal.
Level-1 Allows full access and control of the device including monitoring, diagnostics,
and configuration. The user can add, change, and display configuration options, and
perform device testing.
CAUTION: Before changing the communication ports access level to Level-2 or 3,
make sure that either Telnet Session Access Level or the Modem Ports Port Access
Level is set top Level-1 and at least one Login ID is set to Level-1. Otherwise, access
will be lost. If this occurs, you must reset the unit to the factory defaults and begin the
configuration process again.
Level-2 Allows limited access and control of the device. The user can monitor and
perform diagnostics, display status and configuration option information.
Level-3 Allows limited access with monitoring control only. The user can monitor and
display status and configuration screens only.
Inactivity Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether a user session is disconnected after a specified time of inactivity (no
keyboard activity).
Display Conditions
This option only appears when Port Use is set to Terminal.
Enable Disconnects user session after the specified time of inactivity.
Disable Does not disconnect user session.
Disconnect Time (Minutes)
Possible Settings: 1 60
Default Setting: 10
Specifies the number of minutes of inactivity that can elapse before the session is
disconnected.
Display Conditions
This option only appears when Port Use is set to Terminal.
1 60 Sets the time from 1 to 60 minutes (inclusive).
Table 4-24. Communication Port Options (3 of 5)