Pelco C1528M-F Switch User Manual


 
C1528M-F (6/05) 37
CONFIGURE THE SYSTEM
The CM6800E is shipped from the factory with default programming settings. If the defaults are acceptable, the CM6800E can be operated
without any user programming. However, you may want to program the following basic system settings:
•Time and date.
Camera titles: by default, each camera is titled “CAM #” (# = camera number).
Camera video source: Extended Coaxitron protocol receivers can be operated without any programming changes. For other receiver control
protocols, access the Camera programming screen to select the control type for the device connected to each video input.
•Alarms: The CM6800E is shipped from the factory with the alarm contact enable field set to OFF. To use the alarm features, access the
Alarm programming screens to enable the alarm contact.
In addition, some or all of the following configuration steps may be necessary, depending on your system. Refer to the Programming section for
detailed instructions on programming the CM6800E.
COMMUNICATION PORTS
If you are using any communication port for a device not specified by the default setting, you must access the Port programming screen to change
the settings.
Table F. Default Port Settings
Port Default Settings
COM 1 MGR, RS-232, 56000 baud, no parity, 8 data bits, 1 stop bit
COM 2 BAY2BAY, RS-232, 115000 baud, no parity, 8 data bits, 1 stop bit
COM 3 M, RS-485, 19200 baud, no parity, 8 data bits, 1 stop bit
COM 4 MUX-GENEX, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
COM 5, 6 KBD300, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
COM 7, 8 ASCII, RS-485, 9600 baud, no parity, 8 data bits, 1 stop bit
PTZ-A (Port 9) PTZ-P, RS-422, 4800 baud, no parity, 8 data bits, 1 stop bit
PTZ-B (Port 10) PTZ-P, RS-422, 4800 baud, no parity, 8 data bits, 1 stop bit