SECTION 2.0: INSTALLATION
2.1 PHYSICAL
As previously stated, the connections from 9700-CC1s (CC1-A and -B) to the HS are duplicates of
each other. Except where noted, all the plugs and connectors found on the rear of the CC1 have
corresponding port representations on the subunits of the HS.
9700-CC1 TO CCC (Control Group)
MODEL
MODEL
SERIAL
VOLTS
WATTS
WATTS
FREQ AMPS
DIP SWITCHES LOCATED
BEHIND FRONT PANEL
CROSSOVER
OR
REVERSE CABLE (SUPPLIED)
10 FT (3.05 M)
RJ-45/M-M
CC1-CCC
PORT 5 SERCOM — RJ-45/A-
B
1
CM9760-CCC
(REAR VIEW)
CM9760-CCC
(FRONT VIEW)
CC1 B
CC1 A
PRINTER
COM 1 COM 2
MODEL
SERIAL
VOLTS WATTS
FREQ
AMPS
COM 1 COM 2
PRINTER
1
1
PWR
SYSTEM 9760
PIN 8
PIN 1
LOGGING PRNTR
A
B
A
B
OUT
IN
120-240 VAC 50/60 Hz
C
C
1
SELECT
AB
CC1
KVD
CM9760-CCC
HOT SWITCH
Made in USA
FAULT
A
B
20065
RJ-45 (A & B) DATA LINE INPUT PORTS ARE
RS-422; THE DB9, (A & B) PORTS ARE RS-232.
RECOMMENDED, DATA CABLE HOOKUP IS
THAT REFERENCED AS (1) IN FIGURE 2-1
(CABLE PROVIDED).
THE ALTERNATE HOOKUP (INDICATED BY THE
DOTTED LINE) IS DETAILED IN FIGURE 1-5.
YOU SHOULD USE THE SAME CABLE CON-
FIGURATION FOR EACH ATTACHED CC1.
DIP SWITCH 2 SETTINGS MUST REFLECT THE
COMMUNICATION PROTOCOL OF THE DATA
PATH CHOSEN. (SEE FIGURE 2-4).
PORT ATTACHMENT OF THE HS DATA LINE CON-
NECTION TO SERCOM PORT 5 IS REFLECTED
IN THE COMMS FILE
.
PORT ATTACHMENT REQUIREMENTS FOR
HS-NIU CONFIGURATIONS ARE DISCUSSED
IN APPENDIX 4.4, HS AND NETWORKED CON-
FIGURATIONS.