Pelco C578M-A Switch User Manual


 
28 C578M-A (4/05)
Table D. Diagnostic Displays (continued)
Initialization failure.
One side fails to boot
up or establish
communication with
the HS
B-side fails. B-side
diagnostic will initially
show “Setup Complete”
and then revert to a
port error readout. It
never comes online
(A-OFF). The A-Side is
online (A-MST), asyn-
chronous mode. System
box or error line initially
shows “Setup
Complete” and then
shows port error. If you
try to synch with B-side
at this time (B-side
off-line) System box
will display “Full Synch
Complete”, meaning it
tried to sync. System
error (FAULT LED lit)
will automatically be
generated.
If you take B-side com-
pletely offline, fix, and
reboot, then B-side
diagnostic will show it
as online (A-SLV) with
“Setup Complete”
displayed in the System
box or error line.
HOWEVER, THE B-
SIDE IS NOT YET
SYNCHRONIZED (look
at LEDs). Press CC1 A
once for synchronization.
20092
20093
20094
20095
RECOVERY DISPLAY EXAMPLE
INITIALIZATION ERROR DISPLAY
FUNCTION A-SIDE DIAGNOSTIC B-SIDE DIAGNOSTIC COMMENTS
FUNCTION A-SIDE DIAGNOSTIC B-SIDE DIAGNOSTIC COMMENTS