Chapter 1 – Polycom® RSS™ 4000 Introduction
1-6
To change IP address via RS-232 Console or Telnet:
1 Connect your PC to the RS232 port of the Polycom® RSS™ 4000 with a
serial port cable and activate the console port (115200,8bits).
2 After you logged in to the console port, input the default password
POLYCOM to enter the system.
3 Enter "?" or "help" after the prompt "#" and the system displays available
command information.
4 Change IP address using the command in the format below:
set lan1 ip {dhcp | static <ip> netmask <mask> gw
<gateway>}
For example, to set the IP address of LAN1 port to 172.21.103.29, subnet
mask to 255.255.255.0 and gateway address to 172.21.103.254, enter the
following command:
• The same steps are also applicable for a Telnet connection.
• Only one console (Telnet or RS232) at a time can be connected.
(Optional) Configuring the Gatekeeper Settings
If a gatekeeper is configured on your network, register the Polycom® RSS™
4000 to the gatekeeper to simplify calling.
To register the system to the gatekeeper:
1 Click System Config>Signaling Setting>Gatekeeper in the Web
configuration interface.
2 Set the following parameters in the gatekeeper page:
Table 1-2 Gatekeeper Parameters Description
Parameter Description
Register to Gatekeeper
Indicates whether or not to register the system with the
gatekeeper. You must check this option to set the following
parameters.
Primary (Alternate)
Gatekeeper
Indicates whether or not the device is registered to the
primary (or alternate) gatekeeper.
Gatekeeper IP Address
Specifies the IP address for the primary (or alternate)
gatekeeper.
Gatekeeper Port
Specifies the port number for the primary (or alternate)
gatekeeper.
System Prefix/E164 Sets the E.164 number for the system.
System H.323 Alias Sets the H.323 alias for the system.