Q-Logic MKII-BASE16 Switch User Manual


 
GigWorks MkII-16 Switch Model MKII-BASE16
Installer's/User's Manual 59003-01 Rev. A
Diagnostics/Troubleshooting 4-7
Power-On-Self-Test (POST)
The POST diagnostic program performs the following basic tests:
checksum tests on the Boot firmware located in a PROM and the main
Switch firmware located in FLASH memory
functional hardware tests on internal Switch memory
various read/write register and loopback data-path tests on the Switch logic
Frame Bus and Auto Route logic tests
Auto-Connect and Class 1 Connect logic tests
Switch Management port logic
Arbitrated Loop tests
Heartbeat LED Blink Patterns
Normal (all pass)
If all POST diagnostics pass, the Switch will go to normal operation and the
Heartbeat LED will blink at a steady rate of one (1) blink per second.
Failure Blink Patterns
The Heartbeat LED indicates the error by blinking a series of blinks, pausing for
three seconds, then repeating the blinks. The number of blinks between the three-
second pauses indicates the error. The blinks are at about twice the speed of the
normal Heartbeat.
Test/Failure Descriptions
The following paragraphs describe the tests and their failure indication. If any
POST errors occur, notify Ancor Customer Service or your authorized
maintenance provider. Refer to Appendix B for information about how to
contact Ancor Customer Service.
Repeat pattern
Failure blink pattern
(In this example it is 4)
1 sec.
3 sec.
pause
1 sec.