Q-Logic MKII-BASE16 Switch User Manual


 
GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual 59003-01 Rev. A
Installation 2-3
Installation
Philips-head screws, one in each hole in the Side Fillers.
c. Mount the Brackets. Refer to Figure 2-2. The Switch is shipped with a
package containing cabinet mounting brackets and screws. You may mount
these brackets on the front corners of the chassis or the back corners
depending on whether you want the Switch facing the back or front of the
cabinet.
d. Place the Switch in a 19” EIA rack and secure it with four (4) 10-32
machine screws (not supplied). The Switch must be supported in the rack on
rails or a shelf. If the Switch is supported by a shelf and the vertical space is
sufficient, you may leave the rubber feet on the Switch chassis. If the
vertical space is not sufficient, you may remove the rubber feet by turning
them counterclockwise by hand (or with a flat-blade screwdriver). Be
careful not to obstruct the airflow through the chassis (Allow 165mm (6.5”)
front and back.
e. Replace the Face-plate if possible. If the Switch is facing the front of the
rack the face-plate should fit. Replace the face-plate by aligning its
mounting studs with the appropriate holes in the chassis front and push it
straight back.
Do not obstruct the airflow through the chassis. The airflow enters the front
of the chassis and exits the back.
Figure 2-2 Cabinet Mounting Bracket
Bracket for mounting the
chassis in a rack or cabinet.
Note:
If you mount the Switch in a 19” EIA rack, it must be installed on rails or on a
shelf.