Q-Logic MKII-BASE16 Switch User Manual


 
5-6 Removal/Replacement Procedures
GigWorks MKII-16 Switch Model MKII-BASE16
59003-01 Rev. A Installer's/User's Manual
Power Supply
Power Supply
Removal
If the Switch contains two Power Supplies, either supply is “Hot-Pluggable”.
That is, one supply can be removed while the Switch is powered-up and operating
as long as the other supply is operating properly.
1. Use a large flat-blade screwdriver to turn each of the two Locking-Screws
1/4 turn counterclockwise.
2. Use the Finger-Pulls to pull the Power Supply straight out of the back of the
Switch Chassis. If the Switch contained two power supplies and will now be
operating with only one until the second supply is replaced, install the
Cover Plate over the bay. A Cover Plate came with the Switch.
Power Supply Locking-screws
(one on each side)
Chassis Back
Power Supply
Fan
Finger-Pulls
Danger:
Do not attempt to open the covers of the power supply. Power supplies are not
serviceable and must be replaced as a unit.
Danger:
L’alimentation électrique ne se répare pas. En cas de panne, la remplacer au
complet. Ne pas essayer d’en ouvrir le boîtier.
Gefahr:
Versuchen Sie auf keinen Fall, die Abdeckung des Netzteils zu entfernen. Die
Netzteile sind nicht wartbar. Sie müssen als ganze Einheit ersetzt werden.