Q-Logic MKII-BASE16 Switch User Manual


 
GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual 59003-01 Rev. A
Reference Information A-7
Reference Information
Copper Inter-Enclosure GBIC (active)
Connector: ................................... Style 1 (9 pin D-subminiature, DB-9)
Style 2 (HSSDC, looks like wide phone jack
or RJ45)
Fibre Channel 100-TW-EL-S (shielded dual
parallel pair cable)
Fibre Channel 100-TP-EL-S (shielded dual
twisted pair cable)
Differential Impedance:............... 150 ohms +/- 10 ohms
Transmitted Signal:...................... 1100 - 2000 mV differential PECL
Received Signal:.......................... 400 - 2000 mV differential PECL
Distance: ...................................... 0 - 28 meters with 100-TP-EL-S cable
0 - 33 meters with 100-TW-EL-S cable
Copper Intra-Enclosure GBIC (passive)
Connector: ................................... Style 1 (9 pin D-subminiature, DB-9)
Style 2 (HSSDC, looks like wide phone jack
or RJ45)
Cable:........................................... Fibre Channel 100-TW-EL-S (shielded dual
parallel pair cable)
Fibre Channel 100-TP-EL-S (shielded dual
twisted pair cable)
Differential Impedance:............... 150 ohms +/- 10 ohms
Transmitted Signal:...................... 600 - 2000 mV differential PECL
Received Signal:.......................... 400 - 2000 mV differential PECL
Distance: ...................................... 0 - 11 meters with 100-TP-EL-S cable
0 - 13 meters with 100-TW-EL-S cable