GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual 59003-01 Rev. A
Installation 2-7
Installation
Refer to Appendix A in this manual for Switch power requirements.
a. Connect the power cable to the back of the chassis.
b. Connect the other end of the power cable to a 3 wire, grounded, AC outlet
that delivers power in accordance with the power requirements specified in
Appendix A.
c. Press the Power Button. Refer to Figure 1-2 for its location.
The 3-wire grounded power circuit and the 3-wire power cable provide adequate
grounding for the Switch.
Logic Power Good LED
The Logic Power Good LED on the front of the chassis will light when the
internal power supply is supplying DC power within its normal operating limits
and the Power Button is depressed. Refer to Figure 1-2 for the location of the
LED.
If the Logic Power Good LED fails to light when the Power Button is depressed,
ensure that both ends of the power cord are properly plugged in, the AC power
source is turned ON, and that the input fuses are good.
If you have checked these things and the Power Good LED still is not lit, contact
Ancor Customer Service or your authorized maintenance provider. Do not
proceed to Step 6 unless the Power Good LED is lit.
6. Check the Power-On-Self-Test (POST) Results
When the Power Supply applies DC power to the Switch logic, the logic runs a
Power-On-Self-Test (POST) diagnostic. POST tests the condition of firmware,
memories, data-paths, and Switch logic and uses the Heartbeat LED to indicate
pass or fail conditions. Refer to the Power On Self Test paragraphs in the
Diagnostics and Troubleshooting section (Section 3) of this manual for a
description of POST.
About three seconds after the Power Good LED comes on, POST will be
complete. At this point the Heartbeat LED will start to indicate whether or not
there is a POST error. Check the Heartbeat LED. Figure 1-2 shows the location of
the Heartbeat LED.
If the Heartbeat LED is blinking about once every second, the POST passed and
you may go to the next step.
If the Heartbeat LED is not blinking once every second, the POST failed. Note
what the Heartbeat LED is indicating (by the flash pattern) and contact Ancor
Customer Service or your authorized maintenance provider. Do not proceed to
Note:
Following the connection of AC power to the chassis, the fans start turning
immediately but power is not applied to the logic until the Power button is
pressed.