SATO CL608VA Printer User Manual


 
Form Overlay, Recall
Command Structure <ESC>/
Example: See above
Placement: Must be preceded by all other data and placed just before
the Print Quantity command (<ESC>Q)
Default: None
Command Function To recall the label image from the form overlay memory for printing.
This command recalls a stored image from the overlay memory.
Additional or different data can be printed with the recalled image.
Input to Printer
<ESC>A
<ESC>H0001<ESC>V0125
<ESC>STHIS IS THE STORED IMAGE WITH A BARCODE
<ESC>H0001<ESC>V0165<ESC>B103100*12345*
<ESC>&<ESC>Z
<ESC>A<ESC>H0001<ESC>V0050
<ESC>STHIS IS RECALLING AND ADDING TO THE STORED IMAGE<ESC>/
<ESC>Q1<ESC>Z
Printer Output
Special Notes 1. The overlay is stored using the <ESC>& Form Overlay Store
command (see Page 4-42).
2. If the this command is used with the <ESC>AX Expanded Print
Length command (see page 4-57) the Form Overlay length
cannot exceed 14" (7" for the CL612).
Section 4. Programming Reference
SATOCL Series Printers9001035 Rev. EPage 4-41