Code 39
Command Structure 1:3 ratio: <ESC>B1bbccc* (data) *
2:5 ratio: <ESC>BD1bbccc* (data) *
1:2 ratio: <ESC>D1bbccc* (data) *
bb = Width of narrow element in dots (01-12)
ccc = Bar height in dots (001-600)
* = Required Start and Stop character (asterisk)
(data) = Bar code data (alphanumeric)
Character Set 0-9, A-Z, Space, $, %, +, -, .,/
* (Start/Stop character)
Density Table
Printer
Model
Narrow/
Wide
Ratio
Value of
“bb”
“X”
Dimension
(mils)
Density
(char/inch)
CL412
CL612
1:3013.318.8
1:3026.79.5
2:5016.710.3
1:2013.323.1
1:2026.711.5
CL408
CL608
1:3015.012.7
1:3 02 10.0 6.4
2:5 01 10.0 7.0
1:2015.015.6
1:2 02 10.0 7.8
Example <ESC>H0100<ESC>V0025<ESC>B103100*CODE 39*
<ESC>H0230<ESC>V0130<ESC>XS*CODE 39*
Notes You must add the “*” Start/Stop characters to the data stream. The
printer does not add them automatically.
Appendix B: Bar Code Specifications