Seiko Group IP-6600 Printer User Manual


 
4-2
Temperature Control
The following are three conditions for heater control.
(1) Preset temperature maintaining condition
Function: To heat the paper for reduction of ink dry time,
improvement of ink fixing, and paper winkles
protection.
Status: Status of maintaining each heater temperature at
the preset temperature on the heater control panel.
Conditions: (1) In case the heater ON/OFF setting on the
heater control panel is set to ON and the print
start command is received.
(2) Under the condition (1) above, in case of the
time specified by the delay time after the
print end command was received.
(2) Standby temperature maintaining condition
Function: To shorten time reaching the preset temperature
at print start.
Status: Status of maintaining the heater temperature at the
specified standby temperature (35 °C) for
all heaters.
When the preset temperature is lower than the
specified stand by temperature (35 °C), the printer
maintaines the preset temperature.
Condition: In case of time specified as the standby time after
completion of the preset temperature maintaining
condition.