4-3
Section 4 Heater Controller Operation
Temperature Control
(3) Temperature Control Stop Condition
Function: To prevent useless current consumption, to protect
the paper from being damaged due to the heating
of heaters, and to protect the user from getting
burned due to a touch to the heaters when print is
not performed.
Status: Status of reaching the environmental temperature
slowly.
Condition: In case of conditions other than preset
temperature maintaining condition and standby
temperature maintaining condition.
Start of heating
End of heating
Start of print
End of print
Print heater preset temperature
Rear heater preset temperature
Front heater preset temperature
Standby temperature
Environmental temperature
Keeping of the
preset temperature
Keeping of the
stand by temperature
Keeping of the
preset temperature
Keeping of the
stand by temperature
Stop of the
temperature control
Print
Print
Delay
time
setting
value
Delay
time
setting
value
Standby setting
time
Standby setting
time
(Time)
(Temperature)
Start of heating: The print start command is received and the
heating starts. (The print operation does not
start until the heaters reach the preset tempera-
ture. However, if "WAIT HEATER" is set to
"SKIP", the print operation starts even though
the heaters do not reach the preset temperature.)
Start of print: The heaters reached the preset temperature and
the print operation starts.
End of print: The print end command is received and the
print operation finishes.