Sharp JW-20RS Computer Hardware User Manual


 
9·44
From the previous page
Set top address of register link area on slave station 01 to 77(8) (at standard function)/
number of offset bytes (at memory capacity save function)
Set in parameter addresses 004404 to 004777(8). These top addresses should not overlap the
register link area, flag area, or any area used by other option module.
Slave
station
01
Lower
Upper
File number
·
In case of standard function, set top address by file address(8).
In case of memory capacity save function, set number of offset
bytes.
004404(8)
004405(8)
004406(8)
004407(8)
00(H): The top address is the same address of the master station
regardless of the values set at of 004404 to 004405(8).
80(H): The top address is different from the address of the master
station (Offset is valid).
For the memory capacity save function, set in 80(H).
Slave
station
77(8)
Lower
Upper
File number
·
004774(8)
004775(8)
004776(8)
004777(8)
00(H)
80(H)
In case of setting 0 (the top address is 0440, the same as the address of the master station) in
parameter addresses 004404 to 004407(8) (slave station 01) and the offset byte number 8 and
“offset valid” on the parameter address 004410 to 004413(8) (slave station 02). (Example for 9·40)
Slave
station
01
Write 0 in parameter 004004 to 004007(8) (same as master
station).
Write 00008(D) (offset 8) in parameter addresses
004410 to 004411(8).
Write 00(H) (file 0) in parameter address 004412(8).
Write 80(H) (offset valid) in parameter address 004413(8).
Slave
station
02
Screen display of JW-13PG
File address: OCT (octal), word
File number/flag: HEX (hexadecimal), byte
Set the "same" as or "different" from the
master station: HEX (hexadecimal) , bytes.
To the next page
04011 HEX 00
04012 HEX 00
I PARAM.
>04013 HEX 80