Sharp JW-20RS Computer Hardware User Manual


 
13·3
Setting method (value, example)
(Operations when a slave station error occurs)
Remote I/O operation (communication) stops
The PC continues operation. (Mode 1)
Only normal slave stations will continue
operation (communication).
The PC continues operation. (Mode 2)
Remote I/O operation (communication) stops
The PC continues operation. (Mode 0)
Remote I/O operation (communication) stops
The PC continues operation. (Mode 1)
Only normal slave stations will continue
operation (communication).
The PC continues operation. (Mode 2)
Remote I/O operation (communication) stops
The PC continues operation. (Mode 1)
Only normal slave stations will continue
operation (communication).
The PC continues operation. (Mode 2)
Remote I/O operation (communication) stops
The PC also stops operation. (Mode 0)
Remote I/O operation (communication) stops
The PC continues operation. (Mode 1)
Only normal slave stations will continue
operation (communication).
The PC continues operation. (Mode 2)
001(8)
002(8)
004(8)
005(8)
006(8)
011(8)
012(8)
014(8)
015(8)
016(8)
(Communication
method)
Asynchronous
Synchronism
Asynchronous
Synchronism
000001
000000
: Setting is necessary (1/6)
Address(8)
Set contents
Fix
Manual
JW-PC
ZW-PC
Remote I/O
operation mode
No. of slave
station
connected
(1 to 63 sets)
(Decimal, bytes)
In case of 30 sets 030(D)
13-3 Parameter memory table
(1) JW-20CM
Remote I/O
Initial value of the address 000000, 000001(8) are 00(H).
Fix
Manual