Sharp JW-20RS Computer Hardware User Manual


 
8·38
"Only when using fixed allocation"
Enter the number of slave station I/O points [HEX (hexadecimal), bytes]
(Applied to item on pages 8·31 and 8·35)
· Store the number of I/O points per slave station at parameter address 000200
(8)
.
· The number of slave stations that can be connected varies with the setting for the number of I/O
points per slave station.
Initial value: 00
(H)
· Allocates the number of I/O points per slave station as 64 points per unit or 128 points per unit,
starting from the top address set by the procedure on the previous page.
Ex.: When a remote I/O's top address is 0200 and the number of slave station I/O points is 64.
(When set for 64 points per station using the JW-13PG)
eulavteS stniopO/IforebmuN
tahtseludomforebmuN
.detcennocebnac
00
)H(
noitats/stniop4636ot0
)D(
10
)H(
noitats/stniop82123ot0
)D(
00176 HEX 00
00177 HEX 00
I PARAM.
>00200 HEX 00
Slave station 01
Slave station 02
Slave station 03
Slave station 04
(64 points)
(64 points)
(64 points)
(64 points)
0200
0210
0220
0230
0240
Remote I/O top address
Display the contents of
address 000200
(8)
Write
00
(H)
Screen display of JW-13PG