Table 12-4: S-Registers in CDPD Mode (continued)
Register Description Range Default Units
7
TCP PAD Timeout
This is a timer for the TCP connection (both originate and
answer) and disconnection handshake operations.
For originate connections this timer must also allow for
network registration if the modem is not registered prior to the
Dial command.
For disconnects, if the timer expires prior to a graceful TCP
disconnection, the modem will disconnect without completing
the handshake.
15 – 255 60 Seconds
12
Escape Guard Time
This register determines the minimum idle period before and
after the entry of the escape code sequence (+++ or as defined
in S2). Also, it defines the maximum period, in fiftieths of a
second, allowed between consecutive asynchronous escape
characters (S2) for the time dependent escape sequence to be
considered valid.
If this register is set to 0, the guard time of the escape
sequence is disabled.
0 – 255 0 0.02s
14
Bit Mapped Options (Read Only)
Bit Meaning 0 (clear) 1 (set)
b0 reserved
b1 Echo (E) On Off
b2 Quiet (Q) Disabled Enabled
b3 Verbose (V) Numeric Word
b4 reserved
b5 reserved
b6 reserved
b7 reserved
Defaults shown in bold.
10 (0x0A)
21
Bit Mapped Options (Read Only)
Bits
b 0 Setting of &I (Ring Indicator) (On)
b 2,1 reserved
b 4,3 00 &D0 is selected (Ignore DTR)
01 &D1 is selected (go to cmnd state)
10 &D2 is selected (go to cmnd state off-line)
11 reserved
b 5,6,7 reserved.
Defaults shown in bold.
17 (0x11)
30
PAD Inactivity Timeout
Specifies the amount of time after which a UDP or TCP PAD
session / connection automatically terminates (hangs up) due
to inactivity.
0 Disabled (Default)
1 – 20 Enabled timeout in minutes
0 – 20 00 Minutes