Sierra Wireless DART 300 Modem User Manual


 
References DART 300 Modem
Page 114 2110212 Rev 1.0
Table 12-5: WS-Registers in CDPD Mode (continued)
Register Description Range Default Units
200
Current Channel Number (Read Only)
Reports the current channel number (1 – 1023). Zero (0)
indicates that the modem has failed to connect to a channel.
0 – 1023
201
Registration Result Code (Read Only)
This register is not available during manual registration but
can be read during auto-registration.
Returns the following codes:
Value Meaning
0 Success
1 – 7 Denied by network provider
1 No reason given
2 MD-IS is not capable of handling M-ES at
this time
3 NEI not authorized on this sub-network
4 Insufficient authentication credentials
5 Unsupported authentication credentials
6 NEI has exceeded usage limits
7 Service denied on this sub-network
248 – 253 Registration Progress Codes
248 Wide area Cell transfer
249 No encryption key received
250 Initialization encryption
251 Establishing data link
252 Unable to start data link
253 Awaiting registration confirmation
254 Unregistered by user
255 No response from network
0 – 255
209
Radio Temperature (Read Only)
Returns the internal radio temperature in degrees C. Values
outside the allowed range cause the modem to shut down the
radio to protect it from deviating from specifications. See
Section 11.1.1 for details.
-30 – +75 °C
210
Cell Number (Read Only)
Number of the current CDPD base station
0 – 65535
212
Listening Port
Specifies a port number in UDP/TCP Server mode for packet
reception and auto-answer. Calling clients must use this port
number to reach the DART 300.
If there is an active session, attempts to change this register
will fail with the ERROR result code returned.
1025 –
4999
2100
213
Friend List Index
This points to the entry in the Friends List table for use with
the +WVFRIEND= and +WVFRIEND? commands.
1 – 10 1