Sierra Wireless DART 300 Modem User Manual


 
User’s Guide Specifications
2110212 Rev 1.0 Page 125
14.3. Environmental Specifications
Table 14-4: Environmental Specifications
Operating Temp. -30 to +55ºC
Max ambient: +55ºC @ < 5% transmit duty cycle.
See Section 11.1.2 for full duty cycle restrictions.
Automatic Thermal Shutdown: 75ºC at the radio.
Storage Temp. -40 to +85ºC
Humidity 5% to 95% (non-condensing)
Moisture resistance: Mil-STD202F, 106F
Vibration Operational: IS-19C
Survivability: Mil-STD202
Method 214A,
condition B and D
Shock 1 meter drop to a hard surface
14.4. Application Interface Specifications
Table 14-5: Interfaces
Serial Interface (DTE) 300 – 57,600 bps via +IPR command
AT-Command Interface Hayes Compatible with PCCA Wireless Extensions
UDP PAD Interface PCCA STD-101 Compliant
TCP PAD Interface PCCA STD-101 Compliant
SLIP Interface RFC1055
PPP Interface RFC1661, RFC1662, RFC1332
Object Management Interface Sierra Wireless, Inc. Proprietary