7-4
Field Description for Log Manager/Information Dialog Boxes
Modifying a Log Process
To “fine tune” the parameters for any log process, carry out the steps listed below.
1. Highlight the relevant process in the Log Manager screen.
Table 7-1 Field Description for Log Manager/Information Dialog Boxes
Parameter Description Example
Log Name
2
Process identifier displayed in process list.
Protocol Network transport protocol used to request data, i.e., UDP/IP, IPX or
Ethernet.
UDP
Target Address Network address of the target device. 192.168.1.50
Community
2
Community string used to access the target device. public
Version SNMP version in use by Log Manager (SNMPv1 or SNMPv2c) SNMPV2c
Target Name
1
A user-defined name for this device stored in the Name Database. MIS Server
MIB Module
2
Module to search for variable. Select a specific module or Any module. RFC1213-MIB
MIB Variable Name of the variable being polled, (as defined in the MIB database). hubTotalBytes
Index
3
Index to entry in a table variable. 1
Filter Formula used to filter information. VALUE > 100)
AND(TIME < 120000)
Threshold When true, this formula will generate an event and pass it to the Event
Manager.
R>100
Event Name Name of event enabled by Event Manager when threshold condition
is met.
CRITICAL
Polling Interval Elapsed time between data requests (sec). 30
Start Time Time to start log process. (YYYYMMDD) 20040520
Stop Time Time to stop log process. (YYYYMMDD) 20040521
1 - These variables only appear in the Log Manager dialog box.
2 - These variables only appear in the Log Information dialog box.
3 - If you are unsure if an index is required for a variable, first examine the specification for that variable under the MIB Browser.